Home › Type 1 Diabetes › NCT07296276
Accuracy and Precision of the Continuous Glucose Monitoring System 'CareSens Air 3' in Adult Patients With T1DM
Recruiting
A Prospective, Single Arm, Open-label, Interventional Study to Evaluate the Accuracy and Precision of the Continuous Glucose Monitoring System 'CareSens Air 3' in Adult Patients With Type 1 Diabetes
Who can join
Ages 18 to 65 · All sexes
Full eligibility criteria
Inclusion Criteria: * Adults who are 18-65 years of age, inclusive * Patients with type 1 diabetes who use intensive insulin therapy (multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII) including users of systems with continuous glucose monitoring (CGM) driven automatic adjustment of insulin doses for at least 3 months * Patients who voluntarily decide to participate in the study and provide written informed consent Exclusion Criteria: * The following abnormal skin or skin diseases or skin alterations at the CGM sensor attachment or insertion site: Severe psoriasis, recent burn injury or severe sunburn, severe eczema, severe scar, extensive tattoo, dermatitis herpetiformis, severe rash, Staphylococcus aureus infection. * Allergic contact dermatitis to medical adhesives. * History of frequent catheter abscesses associated with pump therapy. * Severe hypoglycemia events within 3 months prior to screening. Severe hypoglycemia is defined as loss of consciousness or seizure requiring emergency medical treatment due to hypoglycemia. * Hypoglycemia unawareness. * Conditions that predispose to hypoglycemia including inadequately treated thyroid and adrenal disease. * Participants with diabetic ketoacidosis within 3 months prior to screening. * History of epilepsy or syncope within 6 months prior to screening. * Unstable vascular diseases (defined by event or increasing symptoms in the last 6 months) or with insufficient therapy, including: Stroke, transitory cerebral ischemia, ischemic heart disease, peripheral vascular disease, and serious arrhythmia. * Patients with anemia (hemoglobin below normal range). * Patients scheduled for X-ray, MRI, CT or diathermy during the study. * Pregnant or lactating women or those who plan to become pregnant or do not agree to use an adequate method of contraception during the study. * Patients who are currently participating or participated within 2 weeks prior to screening in another study or plan to participate in another study that in the opinion of the investigator would affect the safety of the study participant or the study result. * Patients unwilling to abstain from ingesting the foodstuffs listed in Appendix 3 in excess of the allowed amounts. * Patients with cognitive impairment or who are not suitable for this study or may be at increased risk associated with study participation in the opinion of the investigator. * Wearing of a pace maker or other comparable medical devices. * HbA1c \>9.5%. * Dependency from the sponsor or the clinical investigator. * Unwillingness and/or inability to comply with study procedures.
About the study
This is a prospective, single arm, open-label, interventional, pilot study to evaluate the accuracy and precision of the continuous glucose monitoring (CGM) system of i-SENS, Inc., CareSens Air 3, in adult patients with type 1 diabetes.
What is being tested
- CareSens Air 3 primary insertion (device)
- CareSens Air 3 secondary insertion (device)
Sponsor: i-SENS, Inc. · Participants: 32 · Started: Feb 9, 2026
Contact the study team
Official record on ClinicalTrials.gov — NCT07296276
Locations in the U.S.
| California | Headlands Research AMCR, Escondido (Not yet recruiting) Diablo Clinical Research, Walnut Creek |
| Georgia | Atlanta Diabetes Associates, Atlanta (Not yet recruiting) |
| Washington | Rainier Clinical Reseach Center, Renton |
Conditions
From ClinicalTrials.gov, data retrieved Oct 2, 2026. Each study sets its own eligibility; the study team decides who can join.